SPC-10071 Open-Cell Spray Polyurethane Foam | Water-Blown Sound Insulation

SPC-10071 two-component water-blown open-cell spray polyurethane foam. Ultra-light 9-11 kg/m3, B3 flame retardant, HCFC-free, sound-absorbing and breathable. For interior walls, ceilings, lofts and acoustic insulation. Supplied with TDS/MSDS and matched spray equipment.

SPC-10071 is a two-component, spray-applied open-cell polyurethane foam — a fully water-blown system with very low density (9–11 kg/m³), open-cell structure and B3 flame retardancy. It uses water as the blowing agent, so it produces no ozone-damaging gases and replaces traditional F-11 / HCFC-141B agents. The result is a lightweight, breathable foam that delivers thermal insulation, an air barrier, moisture control and excellent sound absorption — for a quieter, healthier, more energy-efficient interior.

9–11
density
kg/m³
Open
cell, sound-
absorbing
B3
flame
retardant
H₂O
water-blown
(no HCFC)
1:1
volume
ratio

Key Features

Ultra-light open cells
9–11 kg/m³ — far lighter than closed-cell, ideal for large interior areas at low cost.
Excellent sound absorption
Open-cell structure traps air and dampens noise for quieter rooms.
Water-blown & eco-friendly
No F-11 / HCFC-141B, no ozone-damaging gases — a low-carbon building material.
Thermal & air barrier
Insulates and seals air leaks while letting walls breathe.
Fast on-site cure
Cream 3–5 s, gel 6–10 s — sprays and rises in seconds.
Seamless coverage
Fills cavities and contours with no joints or thermal bridges.

Applications

Open-cell spray foam wall sound and thermal insulation
Interior Walls & Partitions
SPC-10071 open-cell spray polyurethane foam interior application
Ceilings & Lofts
Open-cell polyurethane spray foam material texture
Acoustic / Sound-Proofing
Open-cell spray foam insulation in building construction
Residential Construction

Best for interior walls, ceilings, lofts, partitions and acoustic treatment where light weight, sound absorption and breathability matter. For high-R, moisture-resistant, structural insulation choose our closed-cell spray foam (SPC-10072).

Technical Specifications

Item Index (25 °C)
Appearance (polyol) Light yellow to brown transparent liquid
Hydroxyl value 110–120 mg KOH/g
Viscosity (20 °C) 250–300 MPa·s
Specific gravity (20 °C) 1.05–1.10 g/ml
Mixing ratio Volume ratio 1:1
Cream time 3–5 s
Gel time 6–10 s
Core density 9–11 kg/m³
Free-rise density 7–9 kg/m³ (0.45–0.55 lb/ft³)
Flame retardancy B3 level
Storage temperature ≤ 25 °C
Storage stability 6 months

Fully water-blown, open-cell; replaces F-11 / HCFC-141B. Typical values for reference, not a binding specification.

Open-Cell vs Closed-Cell — Which to Choose

  SPC-10071 Open-Cell (this) SPC-10072 Closed-Cell
Density 9–11 kg/m³ (ultra-light) ≥ 35 kg/m³
Best for Sound absorption, interior, low cost High R-value, moisture barrier, structure
Moisture / vapour Breathable Vapour barrier
Blowing agent Water (eco) HFC-245fa

Packaging, Storage & Handling

Packaging
Polyol and isocyanate in iron drums; palletised for export. Bulk on request.
Storage
Keep sealed below 25 °C, cool and dry; shelf life 6 months. Isocyanate reacts with moisture.
Handling & Safety
Use PPE and ventilation; avoid eye/skin contact and vapour. Full MSDS on request.

Explore More Spray & PU Materials

Why BlendPolyol

10+ years in PU raw materials
Specialised blended-polyol & spray-foam supplier serving industry worldwide.
Eco water-blown systems
HCFC-free, low-carbon foam chemistry.
Equipment integration
Matched spray machines and application support.
Global export & fast reply
Export to EU, Latin America, Asia and beyond — reply within 24 hours.

From Sample to Bulk Order

1. Share your project
Tell us the substrate, area and goal (thermal or acoustic) — we recommend a grade.
2. Sample & validate
Trial spray with TDS, MSDS and COA for your tests.
3. Scale to bulk
Confirm the grade and order in bulk with flexible MOQ and tiered lead times.

Frequently Asked Questions

Why choose open-cell over closed-cell?Open-cell SPC-10071 is much lighter (9–11 kg/m³), cheaper to cover large areas, breathable and an excellent sound absorber — ideal for interior walls, ceilings and acoustic work. Closed-cell suits high R-value and moisture-barrier needs.
What blowing agent does it use?Water only — no F-11 or HCFC-141B, no ozone-damaging gases. It is an eco-friendly, low-carbon foam.
How is it applied?Sprayed on site as a two-component (1:1 volume) system with standard plural-component spray equipment; it creams in 3–5 s and gels in 6–10 s.
Do you supply spray equipment too?Yes — matched spray-foam machines and application support are available. We reply within 24 hours.
Need lightweight open-cell spray foam?
Get grade selection, full TDS & MSDS, and a sample — with matched spray equipment if needed.
✓ Water-blown, eco✓ TDS · MSDS · COA✓ Reply within 24 h

Submit Your Sourcing Request

Please complete the form below and our customer support team will be in touch with you shortly. Inquiries submitted through this form will receive priority processing over emails.