Spray Foam Material — Insulation & Coatings
In short: we manufacture two-component spray-applied polyurethane systems — closed-cell insulation (λ ≤23–24 mW/(m·K)), ultra-light open-cell foam (9–11 kg/m³, sound absorption 0.43), spray polyurea coatings and slab-lifting foam. Available HFO and 100% water-blown for regulated markets. Blended in our own plant in China since 2010.
- λ ≤23 mW/(m·K)
- ≥90% closed cell
- HFO & water-blown
- MOQ from 10 kg
- Batch CoA

What Is Spray Polyurethane Foam?
Spray polyurethane foam is applied on site: a blended polyol (component A) and an isocyanate (component B) are metered 1:1 by volume through a heated rig, mixed at the gun, and expand in place within seconds. Because it forms against the substrate, it seals gaps and penetrations that boards and batts leave open.
The one decision that drives everything else is open cell or closed cell: closed-cell foam is denser, insulates more per inch and acts as a vapour barrier; open-cell foam is ultra-light, breathable and absorbs sound.
Spray Foam Systems & Technical Specifications
| System | Cell structure & blowing agent | Density | Key measured data | Reactivity |
|---|---|---|---|---|
| SPC-10072 Closed-cell insulation | Closed cell ≥90% HFC-245fa | ≥35 kg/m³ (core) | λ ≤24 mW/(m·K) · compressive ≥140 kPa · tensile ≥250 kPa · B2 (DIN 4102) | Cream 4–6 s · Gel 10–20 s |
| SPC-10071 Open-cell, water-blown | Open cell ≥99% 100% water-blown — zero ODP | 9–11 kg/m³ (ultra-light) | Sound absorption 0.43 (ISO 10534-2) · breathable · fire class B3 | Cream 3–5 s · Gel 6–10 s |
| HFO-blown closed-cell Low-GWP route | Closed cell ≥90% HFO — zero ODP, low GWP | ≥33 kg/m³ (core) free rise ≥27 | λ ≤23 mW/(m·K) (ASTM C518) — the best lambda of our spray range | Cream 2–6 s · Gel 8–15 s |
| SPC-1031 Spray polyurea | Elastomeric coating (not a foam) | Applied as a membrane | Tensile 18–23 MPa · elongation 375–510% · Shore A85–95 | Gel ~20 s |
Typical values from our published technical data sheets (ASTM and GB/T methods as stated on each TDS). Exact values vary with grade, substrate, rig settings and ambient conditions. Full TDS available on request — no login required.
Key Applications of Our Spray Foam Materials
Building & Wall Insulation
Sprayed in place, the foam fills every cavity and seals air leaks in one pass — no cut-and-fit, no gaps at the studs.
- Closed-cell (SPC-10072): λ ≤24 mW/(m·K) with ≥90% closed cells — maximum R per inch, plus a vapour barrier.
- Open-cell (SPC-10071): ultra-light 9–11 kg/m³, breathable, and a sound-absorption rating of 0.43 — the choice for interior walls and partitions.
- Structural bonus: closed-cell foam stiffens the assembly it is sprayed into.
Roofing
A seamless sprayed roof has no laps or fasteners to leak, and it can be applied straight over most existing roofs.
- Self-flashing: the foam conforms around penetrations, curbs and drains.
- Insulate + waterproof in one system: closed-cell foam for the thermal layer, then a SPC-1031 polyurea topcoat for UV and traffic protection.
- Lightweight: adds insulation without meaningful dead load.
Protective Coatings & Waterproofing
SPC-1031 is a two-component spray polyurea — an elastomeric membrane rather than a foam.
- Fast set: gel in about 20 seconds, so it builds on vertical surfaces and returns to service quickly.
- Tough and elastic: tensile 18–23 MPa, elongation 375–510%, Shore A85–95 — it bridges cracks instead of splitting.
- Where it goes: bridges, roofs, tanks, secondary containment and water works.
Agricultural & Livestock Buildings
A closed-cell spray coating insulates and waterproofs a poultry house or barn in a single layer.
- Stable temperature: keeps the house within range and cuts heating and ventilation cost.
- Washdown-durable: the closed-cell surface resists moisture rather than soaking it up.
- Also used for: livestock barns and greenhouses.
Slab Lifting & Void Filling
Our closed-cell slab-lifting foam raises settled concrete by expanding underneath it.
- Lifts in minutes: injected through small holes; the slab is back in service the same day.
- Density ≥30 kg/m³: carries the load and will not wash out — it is waterproof.
- Where it goes: driveways, pool decks, warehouse and industrial floors.
Blowing Agents: Choose the Compliant Route
Which blowing agent you can use depends on where you sell. We supply all four routes and will tell you which one fits your market.
HFO — Zero ODP, low GWP
The compliant route for regulated markets, and the best lambda we offer (≤23 mW/(m·K)).
100% water-blown — Zero ODP
Open-cell SPC-10071 — no chemical blowing agent at all, just water.
HFC-245fa — Zero ODP, high GWP
Closed-cell SPC-10072. Still permitted in many markets, but being phased down in the US and EU.
HCFC-141b — Being phased out
Legacy grade — we supply it only where it is still permitted.
Frequently Asked Questions
Open-cell or closed-cell — which do I need?
Which blowing agents do you offer for spray foam?
What machine settings do your spray systems need?
Is spray polyurea the same as spray foam?
What is your minimum order quantity?
Can I get the TDS, MSDS and a free sample?
Related Spray Foam Pages
Need a Spray Foam System for Your Rig?
Tell us the application, whether you need open or closed cell, your blowing-agent constraints and your volume — our engineers reply within 24 hours with a formulation and the full TDS.